SGLN-Net: Multimodal Feature Learning with Improved Self-Guided Filtering and a Hybrid Improved LeNet–SqueezeNet Architecture for Parkinson's Disease Detection Using MRI
Keywords:
Parkinson’s Disease Detection; Structural MRI; Self-Guided Filtering; Rician Noise; Local Phase Quantization; Grey Wolf Optimizer; LeNet; SqueezeNet; Hybrid Deep LearningAbstract
Structural magnetic resonance imaging (MRI) is widely available and non-invasive, but the changes that Parkinson's disease (PD) produces on conventional T1-weighted scans are subtle, and they are easily masked by Rician noise, intensity inhomogeneity and inter-scanner variability. This study proposes SGLN-Net, a multimodal feature learning framework that couples image enhancement with complementary handcrafted and deep representations. First, an Improved Self-Guided Filter (ISGF) denoises each slice using the slice itself as guidance, with edge-aware adaptive regularization, iterative refinement and explicit correction of the Rician noise bias. Second, three feature modalities are extracted from the enhanced slices: texture features by an Improved Local Phase Optimization (ILPO) scheme that combines multi-scale decorrelated local phase quantization with monogenic local-phase statistics and tunes its parameters with a Grey Wolf Optimizer; shape features from geometric descriptors, Hu invariants and Zernike moments; and deep features from two branches. Third, a hybrid classifier fuses an Improved LeNet branch with residual squeeze-and-excitation blocks, an ImageNet-initialized SqueezeNet branch and the handcrafted vector through learned branch gating, and subject level predictions are obtained by averaging slice probabilities. On a Shepp–Logan phantom corrupted by Rician noise (σ = 0.05), ISGF raised PSNR from 24.14 dB to 33.92 dB and SSIM from 0.258 to 0.884 over 10 noise realizations, outperforming Gaussian, non-local means and standard self-guided filtering, with most of the gain attributable to Rician bias correction. A leakage-free evaluation protocol on PPMI T1-weighted scans is defined, with subject-level stratified cross-validation, component-wise ablation and re-implemented reference networks; the classification experiments on patient data are in progress, and the paper states the hypotheses and success criteria against which they will be judged.
Downloads
Downloads
Published
Issue
Section
License
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.

