Stone-Preserving Modality-Adaptive Preprocessing and Comparative Deep CNN Frameworkfor Early Detection of Kidney Stones in CT and Ultrasound Images

Authors

  • Dhanesh Kumar Author
  • Donavalli Haritha Author

Keywords:

Kidney stone detection; Computed tomography; Ultrasound; Speckle reduction; Image enhancement; Region of interest; Convolutional neural networks; ConvNeXt; EfficientNet

Abstract

Kidney stone disease affects a large and growing share of the population, and its early detection depends on recognizing small calculi in computed tomography (CT) and ultrasound images that are degraded by quantum noise and speckle. Deep convolutional neural networks (CNNs) report very high accuracy on public kidney CT datasets, but most studies treat preprocessing as a fixed step and do not examine whether denoising removes the very foci that indicate early disease. This study proposes a robust detection framework built around a Stone Preserving Adaptive Enhancement (SPAE) pipeline: modality-specific denoising (non-local means for CT, speckle-reducing anisotropic diffusion for ultrasound) is combined with a multiscale Laplacian-of-Gaussian and top-hat saliency map that restores small bright foci suppressed by denoising, followed by kidney region-of interest (ROI) extraction and contrast-limited adaptive histogram equalization, after which ResNet, DenseNet, EfficientNet and ConvNeXt backbones are compared under a common protocol. The pipeline was validated on synthetic CT and ultrasound kidney phantoms with known stones. Speckle reduction alone lowered small-stone (radius ≤ 2 pixels) recall at about one false positive per image from 80.3% without filtering to 63.1%, whereas SPAE restored it to 76.2%; in CT, SPAE raised small-stone recall from 82.0% with non-local means to 89.1% (120 test phantoms each). ROI extraction achieved mean Dice coefficients of 0.94 for CT and 0.88–0.90 for ultrasound and retained every stone within the cropped region. Noise-reduction quality remained close to the base denoisers (CT PSNR 33.4 versus 34.2 dB at noise SD 0.07). The CNN comparison on public CT and ultrasound datasets is specified with a leakage-controlled protocol, and the experiments are in progress.

Downloads

Download data is not yet available.

Downloads

Published

2026-10-20

How to Cite

Stone-Preserving Modality-Adaptive Preprocessing and Comparative Deep CNN Frameworkfor Early Detection of Kidney Stones in CT and Ultrasound Images . (2026). Minimax Theory and Its Applications, 11(5s), 180-197. https://journalmta.com/index.php/jmta/article/view/685