Stone-Preserving Modality-Adaptive Preprocessing and Comparative Deep CNN Frameworkfor Early Detection of Kidney Stones in CT and Ultrasound Images
Keywords:
Kidney stone detection; Computed tomography; Ultrasound; Speckle reduction; Image enhancement; Region of interest; Convolutional neural networks; ConvNeXt; EfficientNetAbstract
Kidney stone disease affects a large and growing share of the population, and its early detection depends on recognizing small calculi in computed tomography (CT) and ultrasound images that are degraded by quantum noise and speckle. Deep convolutional neural networks (CNNs) report very high accuracy on public kidney CT datasets, but most studies treat preprocessing as a fixed step and do not examine whether denoising removes the very foci that indicate early disease. This study proposes a robust detection framework built around a Stone Preserving Adaptive Enhancement (SPAE) pipeline: modality-specific denoising (non-local means for CT, speckle-reducing anisotropic diffusion for ultrasound) is combined with a multiscale Laplacian-of-Gaussian and top-hat saliency map that restores small bright foci suppressed by denoising, followed by kidney region-of interest (ROI) extraction and contrast-limited adaptive histogram equalization, after which ResNet, DenseNet, EfficientNet and ConvNeXt backbones are compared under a common protocol. The pipeline was validated on synthetic CT and ultrasound kidney phantoms with known stones. Speckle reduction alone lowered small-stone (radius ≤ 2 pixels) recall at about one false positive per image from 80.3% without filtering to 63.1%, whereas SPAE restored it to 76.2%; in CT, SPAE raised small-stone recall from 82.0% with non-local means to 89.1% (120 test phantoms each). ROI extraction achieved mean Dice coefficients of 0.94 for CT and 0.88–0.90 for ultrasound and retained every stone within the cropped region. Noise-reduction quality remained close to the base denoisers (CT PSNR 33.4 versus 34.2 dB at noise SD 0.07). The CNN comparison on public CT and ultrasound datasets is specified with a leakage-controlled protocol, and the experiments are in progress.
Downloads
Downloads
Published
Issue
Section
License
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.