Application of a fuzzy mixed sampling plan for Sterile drug vial testing in the pharmaceutical industry
Keywords:
Fuzzy chain sampling plan, mixed sampling plan, fuzzy acceptance sampling, acceptable quality level, limiting quality level, operating characteristic curve, pharmaceutical quality control.Abstract
Testing every unit is often not an option when inspection is destructive or expensive, yet classical acceptance sampling plans struggle to represent the uncertainty that naturally surrounds a defect rate in such settings. This paper develops a fuzzy mixed sampling plan indexed through the fuzzy Acceptable Quality Level (AQL) and fuzzy Limiting Quality Level (LQL), pairing fuzzy variable sampling at the first stage with a Fuzzy Chain Sampling Plan (FChSP) at the second. The fraction defective is treated as an interval-valued fuzzy number, and the overall acceptance probability is derived analytically and split between the two stages. A further contribution places both design procedures inside a single minimax risk-constrained optimization problem: the AQL-based design turns out to be the exact minimax-optimal solution, while the LQL-based design deliberately settles for a smaller, cheaper sample size, giving up a quantifiable amount of worst-case consumer protection in exchange for less destructive testing. Design tables cover chain indices ???? = 1 to 5 and are demonstrated on sterile drug vial inspection. The AQL-based illustration (p₁ = [0.009, 0.010], pa1 = 0.95,???? = 3) yields parameters (n₁, n₂, k, i) = (4, 26, 2.484, 3), while the LQL-based illustration (p₂ = [0.03, 0.04], pa2 = 0.05,???? = 1) yields (4, 106, 0.8447, 1). As p₁ moves from [0.001, 0.002] up to [0.009, 0.010], the acceptance constant ???? drops from [3.035, 3.283] to [2.484, 2.558] and the second-stage sample size n₂ shrinks from [191, 383] to [38, 43], cutting destructive inspection without giving up the specified producer's and consumer's risks. A larger first-stage sample, from [4, 6] to [9, 11], tightens the interval on ???? by roughly 30%, sharpening precision, and the chain index itself has only a marginal effect on the results. Taken together, the findings point to a framework that is both mathematically well-founded and practical for destructive quality control in pharmaceutical manufacturing.
Downloads
Downloads
Published
Issue
Section
License
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.

